[HIOKI FT3424] 조도계 / LUX METER
HIOKI FT3424 LUX METER
주요특징 (Features)
• LED 조명 측정 대응
• 소방법에 규정되어 있는 비상등이나 피난유도등과 같은 저조도부터 고조도(200,000lx) 까지 커버
• 그림자나 반사에 의한 영향을 피하고 떨어진 장소에서도 측정할 수 있는 타이머 홀드 기능 탑재
• 내부 메모리에 최대 99개 데이터를 저장, PC에 전송하여 작업 효율 향상
상세설명 (Description)
Light Meter with Broad Coverage from Low to High Illuminance
The FT3424 is a light meter designed for an extensive range of applications involving illumination equipment, lighting work and facility management. Capable of testing even LED lighting, the FT3424 provides five measurement ranges, 20 lx to 200,000 lx, to support a wide range of luminance levels.
◈ How to Use the Hioki Lux Meter FT3424
Basic introduction to using a Hioki lux meter
Introduces how to use Hioki's FT3424 lux Meter, from zero-adjustment and the hold function to making measurements. Since the instrument’s memory function lets it store measured values, there’s no need to take notes by hand in the field. In addition, a timer hold function and connection cable make it possible to measure illuminance after moving away from the instrument.
◈ Measure illuminance free of the effects of shadows
1. Timer hold function
Retain the measured value after a user-configured amount of time has
elapsed from the time the TIMER key is pressed. In this way, you can time
measurement to occur after you have moved away from the lux meter so that
measurement is not affected by clothing, shadows, etc.
Timer settings:
Select from 5 / 10 / 15 / 20 / 30 / 45 / 60 sec.
After the set time has elapsed, the measured value is retained. → The backlight turns on and the beep sounds for 3 sec.
2. Measurement with sensor and display units undocked
You can undock the display and sensor units for more convenient use. Simply connect them with the Connection Cable L9820 (option).
◈ Support for measurement of 1 lx makes the FT3424 ideal for low-illuminance measurement
20 lx range measurement resolution 0.01 lx
◈ Memory function makes multipoint measurement a breeze
1. Memory function (up to 99 values)
Save measured values for multiple measurement locations in the instrument’s
internal memory on the spot for later display at your convenience.
There’s no need to take time to jot down a reading on paper for each measurement.
2. Data communications functionality
Transfer data saved in the instrument’s internal memory to a computer via a
USB connection. Data can be saved as a text file.
Technical specifications
Basic specifications |
||
---|---|---|
Standards | DIN 5032-7: 1985 class B, JIS C 1609-1: 2006 general AA class | |
Light receiving element | Silicon photo diode | |
Range selection | Auto/ Manual | |
Linearity | ±2% rdg. (Multiply by 1.5 for display values in excess of 3000 lx.) | |
Accuracy guarantee for temperature and humidity | 21 °C to 27 °C (69.8 °F to 80.6 °F), 75% rh or less (non-condensing) | |
Response time | Auto range: within 5 seconds, Manual range: within 2 seconds | |
D/A output | Output level: 2 V/range f.s. (2.5 V is output when the range f.s. is exceeded.) Output accuracy: ±1% rdg. ±5 mV (at display count) |
|
Functions | Timer hold function, Memory function (Up to 99 measured data can be saved.), Hold, Auto power off function, Buzzer sound, Backlight, Zero adjustment | |
Power supply | LR6 Alkaline battery ×2 (continuous use 300 hours), Max. rated power 500 mVA, or R6 Manganese battery ×2, or USB bus power (5 VDC) | |
Dimensions and mass | 78 mm (3.07 in)W × 170 mm (6.69 in)H × 39 mm (1.54 in)D, 310 g (10.9 oz) (including the batteries) | |
Measurement ranges |
||
Range | Measurement range | Display steps |
20 lx | 0.00 lx to 20.00 lx | 1 count step |
200 lx | 0.0 lx to 200.0 lx | |
2000 lx | 0 lx to 2000 lx | |
20000 lx | 0(0) lx to 2000(0) lx | 10 count step |
200000 lx | 0(00) lx〜2000(00) lx | 100 count step |
Accessary
기본 악세사리 |
---|
• Instruction Manual ×1 • LR6 Alkaline battery ×2 • Sensor cap (with strap) ×1 • Carrying case (soft) ×1 • Strap (for instrument) ×1 • USB cable (0.9 m/2.95 ft) ×1 • CD (USB driver, dedicated computer application software, and communications specifications) ×1 |
- 배송비 : 1,000,000원 이상 구매시 무료배송이며, 미만 주문시 5,000원의 택배비가 청구됩니다.
도서, 산간지방 및 일부지역은 배송비가 추가될 수 있습니다.(퀵, 다마스 배송은 별도 문의부탁드립니다)
- 배송기간 : 배송은 일반적으로 결제후 2~7일이 소요됩니다.(토요일/공휴일 제외, 도서지역 4~8일)
특수제품, 주문제작 및 직수입 상품의 경우 별도 배송일을 안내해 드립니다.
배송예절일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과 차이가 발생할 수 있습니다.
- 본 상품의 배송 가능일은 15일입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.
(단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)
교환/환불 |
환불 |
교환 |
단순변심 |
고객님 부담으로 환불금액에서 왕복 배송비가 차감되어 환불됩니다. |
왕복 배송비 확인 후 박스에 동봉해서 보내주세요. - 일반적으로 교환이나 환불시 10,000원의 왕복배송비가 적용됩니다.(상품에 따라 상이 할 수 있습니다) - 재고가 없는 경우 환불처리 될 수 있습니다. |
제품하자 및 오배송 |
판매자 부담이므로 상품만 보내주시면 됩니다. |
교환/환불이 불가능 한 경우 |
|
환불/교환 요청기간 초과 |
환불/교환 기간 이후 요청하는 경우(배송완료 시점으로부터 15일 초과시) 단, 수령한 상품이 표기 광고의 내용과 다르거나 계약 내용과 다르게 이행된 경우에는 수령한 날로부터 3개월 이내, |
재고가 부족한 경우 |
단순변심으로 교환을 요청했으나, 재고가 부족한 경우(환불 처리 될 수 있습니다) |
특수제품/ 주문제작/ 직수입제품 |
주문/제작 상품의 제작이 이미 진행된 경우, 직수입 제품의 경우 주문서가 들어간 경우 |
분실/ 파손/ 고장/ 오염 발생 | 상품택/ 구성품 분실 및 취급 부주의로 인한 파손/고장/오염 등이 발생한 경우 |
모니터 해상도 차이 | 모니터 해상도 차이로 인하여 색상 등 이미지가 실제와 상이한 경우 |
기타 불가사유 | ① 제품박스가 손상되거나 찢어진 경우 ② 고유팩 포장을 분리하거나 훼손하였을 경우 ③ 렌즈에 이물질 및 지문등의 흔적이 남은 경우 |
<기타 불가 사유 참고 이미지>
|
- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.
- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오.
- 상품 청약철회 가능기간은 상품 수령일로 부터 15일이내 입니다.
- 일부 특수 제품, 주문제작 및 직수입 제품의 경우 교환/반품이 어려울 수 있습니다.
- 구매전 충분히 상담하시고, 신중하게 구매 해 주시기 바랍니다.
- 저희 텍캄몰에서 구매하신 제품과 상품은 정품으로 본사 및 전문점에서 A/S를 받을 수 있습니다.
- 무상 A/S기간에 상관없이 밴드교체 및 유리교체 등 소모품성 및 고객님의 부주의로 인한 파손은 유상 A/S(비용청구)로 처리됩니다.
- A/S 처리방법은 매장으로 방문하시거나 전화해 주시고, 우편이나 택배이용시 배송료는 본인 부담입니다.
- A/S 처리기간은 고장상태와 부품조달 관계로 1주일에서 최장 3개월까지 걸릴 수 있습니다.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?