Keithley 2001
Digital Multimeter / 디지털 멀티미터
7½-Digit High Performance Multimeter
• True 7½-digit resolution based on 28-bit A/D converter
• Exceptional measurement integrity combined with high throughput
• Advanced AC measurements including Peak ACV, AC or AC+DC Coupling, RMS or average, and low frequency RMS
• Multiple measurement display
• Optional plug-in switch cards for multipoint measurements
• Built-in bar graph display
• Provides greater dynamic range, avoiding range-shift errors and delays
• Tests precision components quickly and accurately in production environments
• Reduces the number of instruments in your test system
• Displays multiple measurements such as DC and AC volts and the AC frequency from a single measurement connection simultaneously, reducing the need for additional instruments
• Simplify creating a self-contained, multipoint switch and measure solution
• Tracks reading trends around a target value saving time from off-line measurement analysis
DMM users whose applications demand exceptional resolution, accuracy, and sensitivity combined with high throughput now has attractive alternatives to high priced, high end DMMs. Keithley's 7½-digit Model 2001 High Performance Digital Multimeter not only delivers performance specifications usually associated with instruments that cost thousands more, but it also offers a broad range of functions not typically available from DMMs.
The Model 2001 couples exceptional accuracy (0.0018% basic), resolution, and sensitivity with measurement and mathematical capabilities rarely found in DMMs. Its internal peak detector can catch 1μs spikes, such as power supply spikes and transients, AC line power surges, and short-duration dropouts on components, as well as up to 1MHz for repetitive signals. With the Model 2001, it's easy to measure AC peak value, average, and true rms directly to characterise the signal thoroughly.
DC VOLTS DCV INPUT CHARA CTERISTICS AND ACCURA CY |
|||||||||
Range | Full Scale | Resolution | Default Resolution |
Input Resistance |
Accuracy ±(ppm of reading + ppm of range) |
||||
---|---|---|---|---|---|---|---|---|---|
5 Minutes4 |
24 Hours1 |
90 Days2 |
1 Year2 |
2 Year2 |
|||||
200 mV 3 | ±210.00000 mV | 10 nV | 100 nV | >10 GW | 3 + 3 | 10 + 6 | 25 + 6 | 37 + 6 | 50 + 6 |
2 V | ±2.1000000 V | 100 nV | 1 µV | >10 GW | 2 + 1.5 | 7 + 2 | 18 + 2 | 25 + 2 | 32 + 2 |
20 V | ±21.000000 V | 1 µV | 10 µV | >10 GW | 2 + 1.5 | 7 + 4 | 18 + 4 | 24 + 4 | 32 + 4 |
200 V | ±210.00000 V | 10 µV | 100 µV | 10 MW ±1% | 2 + 1.5 | 13 + 3 | 27 + 3 | 38 + 3 | 52 + 3 |
1000 V | ±1100.0000 V | 100 µV | 1mV | 10 MW ±1% | 10 + 1.5 | 17 + 6 | 31 + 6 | 41 + 6 | 55 + 6 |
Note.
1. For TCAL ±1°C, following 55-minute warm-up. TCAL is ambient temperature at calibration, which is 23°C from factory. 2. For TCAL ±5°C, following 55-minute warm-up. Specifications include factory traceability to US NIST. 3. When properly zeroed using REL function. 4. DCV Transfer Stability typical applications are standard cell comparisons and relative accuracy measurements. Specs apply for 10 power line cycles, 20-reading digital filter, autozero on with type synchronous, fixed range following 2-hour warm-up at full scale to 10% of full scale, at TREF ±1°C (TREF is the initial ambient temperature). Specifications on the 1000V range are for measurements within 5% of the initial measurement value and following measurement settling |
AC VOLTS | ||||||||||
Normal Mode RMS1 90 Days, ±2°C from last AC self-cal for 1% to 100% of range2 ±(% of reading + % of range) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Range | 20–50Hz | 50–100Hz | 0.1–2kHz | 2–10kHz | 10–30kHz | 10–30kHz | 50–100kHz | 100–200kHz | 0.2–1MHz | 0.2–1MHz |
200 mV | 0.25 + 0.015 | 0.07 + 0.015 | 0.03 + 0.015 | 0.03 + 0.015 | 0.035 + 0.015 | 0.05 + 0.015 | 0.3 + 0.015 | 0.75 + 0.025 | 2 + 0.1 | 5 + 0.2 |
2 V | 0.25 + 0.015 | 0.07 + 0.015 | 0.03 + 0.015 | 0.03 + 0.015 | 0.035 + 0.015 | 0.05 + 0.015 | 0.3 + 0.015 | 0.75 + 0.025 | 2 + 0.1 | 5 + 0.2 |
20 V | 0.25 + 0.015 | 0.07 + 0.015 | 0.04 + 0.015 | 0.06 + 0.015 | 0.08 + 0.015 | 0.1 + 0.015 | 0.3 + 0.015 | 0.75 + 0.025 | 4 + 0.2 | 7 + 0.24 |
200 V3 | 0.25 + 0.015 | 0.07 + 0.015 | 0.04 + 0.015 | 0.06 + 0.015 | 0.08 + 0.015 | 0.1 + 0.015 | 0.3 + 0.015 | 0.75 + 0.0254 | 4 + 0.24 | |
750 V3 | 0.25 + 0.015 | 0.1 + 0.015 | 0.08 + 0.015 | 0.09 + 0.015 | 0.12 + 0.015 | 0.15 + 0.0154 | 0.5 + 0.0154 | |||
Note. 1. Specifications apply for sinewave input, AC + DC coupling, 1 power line cycle, digital filter off, following 55 minute warm-up. |
OHMS TWO-WIRE AND FOUR-WIRE OHMS (2W and 4W Ohms Functions) 6 |
||||||||
Range | Full Scale | Resolution | Default Resolution |
Current Source1 |
Resistance Accuracy 3 ±(ppm of reading + ppm of range) |
|||
---|---|---|---|---|---|---|---|---|
24 Hours4 |
90 Days5 |
1 Year5 |
2 Year5 |
|||||
20 Ω | 21.000000 Ω | 1 µΩ | 100 Ω | 9.2 mA | 29 + 7 | 52 + 7 | 72 + 7 | 110 + 7 |
200 Ω | 210.00000 Ω | 10 µΩ | 100 µΩ | 0.98mA | 24 + 7 | 36 + 7 | 56 + 7 | 90 + 7 |
2 kΩ | 2100.0000 kΩ | 100 µΩ | 1 mΩ | 0.98mA | 22 + 4 | 33 + 4 | 50 + 4 | 80 + 4.5 |
20 kΩ | 21.000000 kΩ | 1 mΩ | 10 mΩ | 89 µA | 19 + 4 | 32 + 4 | 50 + 4 | 80 + 4.5 |
200 kΩ | 210.00000 kΩ | 10 mΩ | 100 mΩ | 7 µA | 20 + 4.5 | 72 + 4.5 | 90 + 4.5 | 130 + 5 |
2 MΩ 2 | 2.1000000 MΩ | 100 mΩ | 1 Ω | 770 nA | 50 + 4.5 | 110 + 4.5 | 160 + 4.5 | 230 + 5 |
20 MΩ 2 | 21.000000 MΩ | 1 Ω | 10 Ω | 70 nA | 160 + 4.5 | 560 + 4.5 | 900 + 4.5 | 1100 + 5 |
200 MΩ 2 | 210.00000 MΩ | 10 Ω | 100 Ω | 4.4 nA | 3000 + 100 | 10000 +100 | 20000 + 100 | 30000 + 100 |
1 GΩ 2 | 1.0500000 GΩ | 100 Ω | 1 kΩ | 4.4 nA | 9000 + 100 | 20000 +100 | 40000 + 100 | 60000 + 100 |
Note.
1. Current source is typically ±9% absolute accuracy. 2. For 2-wire mode. 3. Specifications are for 1 power line cycle, 10 reading digital filter, Auto Zero on, 4-wire mode, offset compensation on (for 20W to 20kW ranges). 4. For TCAL ±1°C, following 55 minute warm-up. TCAL is ambient temperature at calibration (23°C at the factory). 5. For TCAL ±5°C, following 55-minute warm-up. Specifications include traceability to US NIST. 6. When measuring resistance of |
DC AMPS DCI INPUT CHARA CTERISTICS AND ACCURA CY4 |
||||||||
Range | Full Scale | Resolution | Default Resolution |
Current Source1 |
Resistance Accuracy 1 ±(ppm of reading + ppm of range) |
|||
---|---|---|---|---|---|---|---|---|
24 Hours2 |
90 Days3 |
1 Year3 |
2 Year3 |
|||||
200 µA | 210.00000 µA | 10 pA | 100 pA | 0.25 V | 63 + 25 | 300 + 25 | 500 + 25 | 1350 + 25 |
2 mA | 2.1000000 mA | 100 pA | 1 nA | 0.31 V | 64 + 20 | 300 + 20 | 400 + 20 | 750 + 20 |
20 mA | 21.000000 mA | 1 nA | 10 nA | 0.4 V | 65 + 20 | 300 + 20 | 400 + 20 | 750 + 20 |
200 mA | 210.00000 mA | 10 nA | 100 nA | 0.5 V | 96 + 20 | 300 + 20 | 500 + 20 | 750 + 20 |
2 A | 2.1000000 A | 100 nA | 1 µA | 1.5 V | 500 + 20 | 600 + 20 | 900 + 20 | 1350 + 20 |
Note.
1. Specifications are for 1 power line cycle, Auto Zero on, 10 reading digital filter. 2. For TCAL ±1°C, following 55 minute warm-up. 3. For TCAL ±5°C, following 55 minute warm-up. Specifications include traceability to US NIST. 4. Add 50 ppm of range for current above 0.5A for self heating. 6. Actual maximum voltage burden = (maximum voltage burden) × (1MEASURED/1FULL SCALE). |
AC AMPS | |||||||
ACI ACCURA CY 1, 2 90 Days, 1 Year or 2 Years, TCAL ±5°C, for 5% to 100% of range, ±(% of reading + % of range) |
|||||||
---|---|---|---|---|---|---|---|
Range | 20–50Hz | 50Hz– 200Hz | 200Hz– 1kHz | 1kHz– 10kHz | 10kHz– 30kHz3 | 30kHz– 50kHz3 | 50kHz– 100kHz3 |
200 µA | 0.35 + 0.015 | 0.2 + 0.015 | 0.4 + 0.015 | 0.5 + 0.015 | |||
2 mA | 0.3 + 0.015 | 0.15 + 0.015 | 0.12 + 0.015 | 0.12 + 0.015 | 0.25 + 0.015 | 0.3 + 0.015 | 0.5 + 0.015 |
20 mA | 0.3 + 0.015 | 0.15 + 0.015 | 0.12 + 0.015 | 0.12 + 0.015 | 0.25 + 0.015 | 0.3 + 0.015 | 0.5 + 0.015 |
200 mA | 0.3 + 0.015 | 0.15 + 0.015 | 0.12 + 0.015 | 0.15 + 0.015 | 0.5 + 0.015 | 1 + 0.015 | 3 + 0.015 |
2 A | 0.35 + 0.015 | 0.2 + 0.015 | 0.3 + 0.015 | 0.45 + 0.015 | 1.5 + 0.015 | 4 + 0.015 | |
Note. 1. Specifications apply for sinewave input, AC+DC coupling, 1 power line cycle, digital filter off, following 55 minute warm-up. |
GENERAL | ||
FREQUENCY COUNTER | AC Voltage Input | 1Hz–15MHz. |
---|---|---|
ACCURACY | ±(0.03% of reading). | |
DC IN-CIRCUIT CURR ENT |
TYPICAL RANGES | Current: 100µA to 12A. Trace Resistance: 1mW to 10W typical. |
Accuracy | ±(5% + 2 counts). For 1 power line cycle, Auto Zero on, 10 reading digital filter, TCAL±5°C, after being properly zeroed. 90 days, 1 year or 2 years. | |
TEMPERA TURE | Built-in linearization for J, K, N, T, E, R, S, B thermocouple types to ITS-90 and 100W platinum RTDs DIN 43 760 or IPTS-68. | |
POWER |
Voltage | 90–134V and 180–250V, universal self-selecting. |
Frequency | 50Hz, 60Hz, or 400Hz self-identifying. | |
Consumption | <55VA | |
ENVIRONMENTAL | Operating Temperature | 0° to 50°C. |
Storage Temperature | –40° to 70°C | |
Humidity | 80% R.H., 0° to 35°C, per MIL-T-28800E1 Para 4.5.5.1.2. | |
PHYSICAL | Case Dimensions | 90mm high × 214mm wide × 369mm deep (3½ in. × 8½ in. × 14½ in.). |
Net Weight | <4.2kg (<9.2 lbs.). | |
Shipping Weight | <9.1kg (<20 lbs.). | |
STANDARDS | EMI/RFI | Conforms to VDE 0871B (per Vfg 1046/1984), IEC 801-2. Meets FCC part 15 Class B, CISPR-22 (EN55022) |
Safety | Conforms to IEC348, CAN/CSA-C22.2. No. 231, MIL-T-28800E1 . Designed to UL1244. | |
Note. 1. For MIL-T-28800E, applies to Type III, Class 5, Style E |
- 배송비 : 1,000,000원 이상 구매시 무료배송이며, 미만 주문시 5,000원의 택배비가 청구됩니다.
도서, 산간지방 및 일부지역은 배송비가 추가될 수 있습니다.(퀵, 다마스 배송은 별도 문의부탁드립니다)
- 배송기간 : 배송은 일반적으로 결제후 2~7일이 소요됩니다.(토요일/공휴일 제외, 도서지역 4~8일)
특수제품, 주문제작 및 직수입 상품의 경우 별도 배송일을 안내해 드립니다.
배송예절일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과 차이가 발생할 수 있습니다.
- 본 상품의 배송 가능일은 15일입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.
(단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)
교환/환불 |
환불 |
교환 |
단순변심 |
고객님 부담으로 환불금액에서 왕복 배송비가 차감되어 환불됩니다. |
왕복 배송비 확인 후 박스에 동봉해서 보내주세요. - 일반적으로 교환이나 환불시 10,000원의 왕복배송비가 적용됩니다.(상품에 따라 상이 할 수 있습니다) - 재고가 없는 경우 환불처리 될 수 있습니다. |
제품하자 및 오배송 |
판매자 부담이므로 상품만 보내주시면 됩니다. |
교환/환불이 불가능 한 경우 |
|
환불/교환 요청기간 초과 |
환불/교환 기간 이후 요청하는 경우(배송완료 시점으로부터 15일 초과시) 단, 수령한 상품이 표기 광고의 내용과 다르거나 계약 내용과 다르게 이행된 경우에는 수령한 날로부터 3개월 이내, |
재고가 부족한 경우 |
단순변심으로 교환을 요청했으나, 재고가 부족한 경우(환불 처리 될 수 있습니다) |
특수제품/ 주문제작/ 직수입제품 |
주문/제작 상품의 제작이 이미 진행된 경우, 직수입 제품의 경우 주문서가 들어간 경우 |
분실/ 파손/ 고장/ 오염 발생 | 상품택/ 구성품 분실 및 취급 부주의로 인한 파손/고장/오염 등이 발생한 경우 |
모니터 해상도 차이 | 모니터 해상도 차이로 인하여 색상 등 이미지가 실제와 상이한 경우 |
기타 불가사유 | ① 제품박스가 손상되거나 찢어진 경우 ② 고유팩 포장을 분리하거나 훼손하였을 경우 ③ 렌즈에 이물질 및 지문등의 흔적이 남은 경우 |
<기타 불가 사유 참고 이미지>
|
- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.
- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오.
- 상품 청약철회 가능기간은 상품 수령일로 부터 15일이내 입니다.
- 일부 특수 제품, 주문제작 및 직수입 제품의 경우 교환/반품이 어려울 수 있습니다.
- 구매전 충분히 상담하시고, 신중하게 구매 해 주시기 바랍니다.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?